You are using an out of date browser. If you want just the spider gasket, it is part number SPX0715D; if you want the gasket kit, including the spring, you should choose, I am not sure what type of valve I have, it only says SP 71. Reassemble the same way but in reverse. <<7FFE2592ECB2B2110A0050BACE18FF7F>]/Prev 707785/XRefStm 2112>> in forum Pool Equipment & Operations, Pool Construction, Equipment, Operations, Seasonal Care (P). So the other day I was out at the equipment pad and I happened to notice the dirt looked a little different under the plumbing where the two return-side diverter valves are (one of the benefits of living in a desert is that we dont have grass to mask all our water leak problems). If water is pouring from the top of the valve, changing the spider gasket will not correct the issue. Thanks, Pentair FNS filter - Hi-flow valve leaking out to backwash. JavaScript is disabled. 0000087069 00000 n Posted: 9/10/2020, Steven G 0000068961 00000 n Excessive pressure? The sight lass is the little clear bottle or view glass that allows you to see when the backwash water becomes clear, so you know when to stop backwashing. Please consider. Hayward Pump overflowing/leaking from the cover, With over 300,000 members, TFP is the largest and most influential pool & spa website on the Internet. The only way to figure it out is to take it apart andinspect the port. 0000005798 00000 n 0000008323 00000 n Leaking Air Relief It may not display this or other websites correctly. Thank you so much for watching! 5. First remove the center rod(it is threaded in)and manifold. I can begin the project tomorrow. <> The sand filter is model S310T2. 0000148605 00000 n 5 out of the five times I have backwashed my filter, the push/pull valve has developed a small leak at the top around base of the handle. I already replied to this question but don't see it after 24 hours, so ill answer you again Yes, as stated in my original post, that part is new. LEAK TRAC 2400 W/WIRELESS TECH ANDERSON. Same here. I have an SP 710 X32. endobj If you are having trouble finding the valve # on the label then you may be able to find a SP or SPX part # molded into the plastic of the body of the valve or the handle. i have a Hayward SP 710XR50 variflo valve about twenty years old. Some DE filters also have a large o-ring on the drain plug. <>/Metadata 65 0 R/Pages 64 0 R/StructTreeRoot 67 0 R/Type/Catalog/ViewerPreferences<>>> endobj Do you have this model? Or fastest delivery Fri, Apr 14. The replacement valve for your SP0714G11 valve is the SP714T or the. You may find it at the end of the backwash hose, out in the yard. If we can do that, that should narrow the field to one or two possibilities. startxref <. Any others that might drop in and fit? Posted: 9/3/2020, InyoPools Product Specialist Matt S. It is being practiced by thousands of pool owners just like you. 4. Before you start ordering parts, you should open the valve to make sure the gasket is actually the issue. Posted: 8/3/2021, Mike D Hello , This is an inactive thread. Hope it makes sense. You could inspect the o-ring and see if there's anything abnormal about it. Next remove the backwash handle,compression ring and tank. Posted: 8/17/2020, InyoPools Product Specialist Matt S. Thanks for your help. Channel locks would have been a terrible ideaI'm glad it stopped. We are a registered 501(c)3 non-profit that is funded by user donations. If the valve handle is slack orjiggly, then it is likely the former. %PDF-1.4 % https://www.google.com/url?sa=t&rct=j&q=&esrc=s&source=web&cd=4&cad=rja&uact=8&ved=0ahUKEwiwk9-54OLSAhXDNSYKHR8mDBQQFgi5ATAD&url=http%3A%2F%2Fwww.pentairpool.com%2Fpdfs%2F270163.C-TwoPositionSlideValve.pdf&usg=AFQjCNHF4czLwtNOg-J86In80y83JSTUyw&sig2=-oHPgpRNx3Z8LDw-UcQvFg&bvm=bv.149760088,d.eWE, https://www.google.com/url?sa=t&rct=j&q=&esrc=s&source=web&cd=2&cad=rja&uact=8&ved=0ahUKEwjI8oOQ4-LSAhWGNiYKHVmOBx0QFgglMAE&url=https%3A%2F%2Fwww.physics.harvard.edu%2Fuploads%2Ffiles%2Fmachineshop%2Fepm_oring_handbook.pdf&usg=AFQjCNGhn7SJlwDBQC6FOik17KuUwNxMtA&sig2=WsT1o4kYPJ9NY8BSvZICkg. Water chemistry out of wack? How To Repair Rebuild Leaking Hayward Backwash Push Pull Valve For Swimming Pool Spa Filter KungFuMaintenance 53.5K subscribers Subscribe 24K views 6 years ago Kung Fu Maintenance Shows How To. pieces, where the face of the Slide V alve union. Just build it L shaped. 04.11.2023. unions glued on 1 12 Ordering Information PRE-PLUMBED VALVES If you have egg type, they have 6 or 8 clamps. Clogged filter pump impeller. Water was leaking from my backwash tube while the pump was running. Each time, the PB has sent the warranty people out to repair it. instructions for how to enable JavaScript in your web browser, Click Here to View Hayward MultiportValve Part Diagrams, Click Here to View AllMultiportValve Part Diagrams, Click Here to View ourSpider Gasket EZ Find Chart, Click Here to View Hayward's SP714T Valve Parts, How to replace a Hayward slide valve handle & piston assembly, How to replace a Hayward slide valve O-ring, Click Here to View HaywardMultiportValve Part Diagrams, Hayward Multiport Vari-Flow 1-1/2" SP-710X, SP-712, SP-711 1976-Current, Diverter w/ Spider Gasket for Hayward SP0714T - SPX714CA, Top Mount Valve for Hayward Sand 2" (SP071621) - 27518-204-000, Hayward Multiport Vari-Flow 1-1/2" SP-710X, SP-712, SP-711 1976-Current Parts Diagram, replacement parts for 100 Inline and Offline Series. 0000022414 00000 n You must log in or register to reply here. Mine is doing the exact same thing! The problem could be a loose diverter spring or a damaged spider gasket. 0000001676 00000 n I suspect the variflo valve gasket is worn because professional pool guys have replaced the DE grids with brand new grids and a check of the entire filter shows no problems. Pentair as well. Push pull DE valve causing blowback on FNS PLUS? Maybe the pressure allowed it to settled in? 2. 0000012391 00000 n Posted: 5/24/2021, Anonymous Pentair / American (4) Valves (1050) Check Valves (27) Control / Diverter Valves (33) . Case closed. will connect to the lter bulkheads (see Figure 2). I called today to have it replaced under warranty a second time! Is this something I can do myself, I'm pretty handy. Have you checked to see if the valve's diverter spring/stem is damaged? The seal is created by the two o-rings - the one on the right mates to the upper surface of the valve cover and the one on the left mates to the bottom of the diverter shaft. Diverter valve shaft with o-rings and split ring. Place the o-rings on the face of the union tail. ^@ rvT6.f" C!/O@[tE@&6Nqp[l`ZGGG[ y0I jhhZZFG@I> `d1V3aTa`f0;0IOBTNLPYS&T:*xM]FW I assume that it is the seal on the valve. Empty filter of water by moving valve handle to backwash position and removing filter drain plug. Spin the handle while holding the rotor and it should break loose. Helpful information for us would be any part #s off of the valve, the filter manufacture name, the filter model name, filter model #, filter square footage, number of positions the valve can be set to, plumbing size going into the valve and filter type (i.e. ?? If the stem through the center is leaking there are some parts to change on the valve stem. I have a Pentair (Pac Fab) series 2000 DE filter with built in backwash valve that is leaking out the backwash port at a rate of 6 or 7 drops per minute. 0000004796 00000 n Did you check the handle to determine if it is loose/jigglingwhich can be a sign of a baddiverterspring. If it is brand new and leaking, then it could be a defective valve. Filter. The silicone won't wreck the gasket or seal the filter housing. SWG Type Jandy Aquapure 1400 Mar 18, 2017 #1 OK, need to input. It may not display this or other websites correctly. Several problems though -. 0000170141 00000 n JavaScript is disabled. Ray ID: 7b9c6cb368cb5ab2 Hi Low water flow when switched t. 8. 0000147593 00000 n Feel free to post a comment at the bottom of this guide with as much information about your filter as possible and we should be able to help identify your valve. First, turn off the swimming pool's filter pump. 0000031874 00000 n 0000041347 00000 n 0000008512 00000 n Confirm correct valve is being used; DE valves for DE filters and Sand valves for Sand filters. Posted: 6/4/2021, Martha Perez How do you lubricate or replace it. I have the top mount Hayward SP type diverter. Carton Wt. 4.5 (114) $11994$125.99. 643 0 obj Posted: 5/12/2022, InyoPools Product Specialist Matt S. unions glued on 1 12 263081 Valve for D.E., inlet port on bottom, Pentair 2 in. Hello , This is an inactive thread. check out the. Is it loose? Unless you wereturning the valve handle when the pump was running, the gasket should not have failed this early. Multiport Valve Leaks Around The Cover When the cover on your multiport valve leaks, the first thing you should check is your system's pressure. For a better experience, please enable JavaScript in your browser before proceeding. You will also want to replace the rotor shaft o ring and valve body o ring. What do I need to fix this? Sounds like you did try everything and did it all right. KEY FEATURES Solid, injection-molded PVC housing Permits leak-free solvent welds to PVC piping. Can you help me, Your valve is an SP714T.For future readers: If your valves model number begins with SP714 with a combination of numbers or letersafter it, there's a very good chance you have the, I have a sp714-a hayward vari-flo xl valve did not see that listed top mount sand filter, The SP714A is not a model number, it is the part number for the. Pentair Earns 2023 ENERGY STAR Partner of the Year - Sustained Excellence Award. 0000006983 00000 n It looked to me that if the O rings were failing that it would leak out of the valve itself, rather than the waste line. The valve top was cracked around the bolt holes and leaking so I replaced the valve top and the gasket. Posted: 8/25/2020, Kim Please consider. I tried adjusting the valve slightly, to see if that would stop the dripping, but it didn't. Before you start For guidance in backwash valve repair, start with this step-by-step pictorial. Recommended fix for this, please! Then remove the handle extension from the rotor shaft. Posted: 5/4/2021, Tim It is being practiced by thousands of pool owners just like you. I have a Vari-Flo XL Valve, and it leaks from around where the pump hose is connected. The backwash valve is the valve which is mounted on either the top or side of your filter tank and are specifically used clean sand filters or DE filters. Pay attention to the orientation of the key seal relative to the handle position- it is possible to put it on backwards. 0000131885 00000 n It it seeping or does it come out dripping continuously? Any idea on part I need maybe number? Is it pressed in? 0000005215 00000 n Pentair,s fan - Please let me know what parts numbers do I need to rebuild the top assembly of the hi flow valve model 260067 - 2 inch (white valve with black handle) Hello in order for your question to be answer correctly, we need for you to please contact us on our website or call Technical Services at 800-831-7133. Would be nice to have something. I searched the forums for a similar problem but only saw threads discussing the issue of water leaking from the waste line when there was a multiport or a push/pull type backwash valve involved. There are usually six to eight screws or bolts, and you may need a wrench to grip nuts from beneath as you loosen the screws or bolts from above. Improper plumbing valve settings. Couple of clips on the wall, and a couple of steel tent stakes with clips, and youll be in business. hb```e`` @1v27Ss; i replaced my spider gasket it still leaks and wont backwash. 0000004288 00000 n 4. 0000022939 00000 n The diverter valve is on the pipe coming from the pump basket and diverts the flow either to the filter or to a waste line. and the valve # will be located in this box. The reason is simple: TFPC (Trouble Free Pool Care) is a methodology, not a product that you must purchase. What is the correct gasket for it? If the handle is stiff, then I would open the valve to find out if the spider gasket or something else is the cause.With either of those options, you should consult the. 0000094363 00000 n I've put on new gaskets and it still leaks with the expensive non petroleum pool lube gasket material. I see that I can purchase the seal separately from the valve body or together as a assy. Just wanted to add a closing comment: to this: after a few days of letting the pump filter as normal while i debated on what to do, the leak stopped on its own. I invested in a good rubber mallet to knock the band into seat as I tightened it down. However, I wanted to confirm that in case I could get away with buying a couple of dollar parts, instead of a $45.00 + plus part, which is more than the whole valve costs at Amazon. Use the cover plate screws to compress the spring; tighten them all halfway and then finish them. Does the handle turn at all? 5 out of the five times I have backwashed my filter, the push/pull valve has developed a small leak at the top around base of the handle. Unfortunately, all of Hayward's multiport valves begin with SP71. 0000118290 00000 n You are using an out of date browser. 0000137721 00000 n Indem Sie auf Annehmen klicken, stimmen Sie dem zu. Posted: 5/13/2021, InyoPools Product Specialist Matt S. The rotor comes out after you remove the handle and extension. 0000078594 00000 n The plastic knob is as tight as i can get it by hand. Am I in need of a new spider valve? The filter is only about 7 yrs old. FREE delivery Apr 13 - 17. You are using an out of date browser. Posted: 7/31/2020, InyoPools Product Specialist Matt S. How do you get the backwash handle off the rotary shaft? For a better experience, please enable JavaScript in your browser before proceeding. Sie knnen nicht notwendige Cookies ber Einstellungen verwalten ablehnen. Pentair to Release First Quarter 2023 Earnings and Host Investor Conference Call on April 27. 0000002112 00000 n . I have been noticing DE powder on the pool bottom for the last couple of years. 0000097986 00000 n No additional tightness is required. The stem o-rings for the SP710 valve are listed as key 8A on the following parts diagram: Im trying to find a replacement spider gasket for my Hayward vari-flo XL sand filter valvethe number on the top is SP0714G11Many help would be appreciated! 576 69 However, if I move the handle just a quarter of an inch countercloskwise ( toward the backwash position) the leaking stops. Install valve to filter by securing bulkhead nuts on valve to fittings on the filter. 3. In this video we. Posted: 7/18/2021, InyoPools Product Specialist Matt S. We can try to narrow down the choices if you can identify the model number of your filter. Dealing with Stains & Metals, . Winterizing 1. Pentair (NYSE: PNR), a leading provider of water treatment and sustainable . Typically this is located on the label on the top of the valve, normally there is a box named model no. This valve is the source of water for the softener. One-piece handle Corrective Action: Verify water pump is on. Posted: 5/14/2021, InyoPools Product Specialist Matt S. http://www.pentairpool.com/pool-ownection.php?s=51, Pool Water: Treatment, Testing & Problems (P), Testing and Adjusting Pool Water Chemistry, Using Chlorine and Chlorinating Chemicals, Salt Generators (SWCG) & other Chlorine Feeders. The spider gasket directs the flow of water to your multiport valve. 0000007547 00000 n 0000009631 00000 n 0000097361 00000 n What do i check next? Its still leaking. Posted: 6/24/2020, InyoPools Product Specialist Matt S. However, if your pressure is normal, double check the cover screws. My model number shows SP0714G11M and I can't find it. Simply put - we offer water expertise. 0000112472 00000 n Thank god. 0000006216 00000 n 578 0 obj backwash position for pentair 2" slide valve? 0000069521 00000 n 0000131251 00000 n JavaScript is disabled. The majority of Hayward valve part #s start with this prefix SP7. I know this post is a year old, but I just learned something that may help others. Full removal and installation of Spider gasket in a Pentair or Hayward pool sand filter multiport valve.. http://www.dirtymaintenancenation.com/Lex Vance is a participant in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to amazon.com.This video contains an affiliate link, which means that if you click on the link and make a purchase, I'll receive a small commission. You must log in or register to reply here. Posted: 9/2/2020, InyoPools Product Specialist Matt S. If your sight glass is leaking during backwashing, it may be missing the small gasket that prevents this, or you may notice a small crack. My backwash valve for SP714-A keeps leaking. Cloudflare is currently unable to resolve your requested domain. Houzz nutzt Cookies und hnliche Technologien, um Ihre Benutzererfahrung zu personalisieren, Ihnen relevante Inhalte bereitzustellen und die Produkte und Dienstleistungen zu verbessern. It leaks at the top of the shaft at the handle when closed in the filter position. 1. Sprayed wd40 on the band to help it slide around the housing and clamp tighter. Anytime the filter is on in filter mode it leaks water out the waste line. Remove the o-rings (2 total) from the packaging. Plumb pump piping to center pipe in valve. Pentair plc (NYSE:PNR), a leader in helping the world sustainably move, imp. Report. Make managing your water easier and more cost effective than ever before. I feel your pain! Hi. 3. 0000147632 00000 n Came back out and the leaks stopped. %%EOF Installed it back and went around the top and bottom gaps with more lube to help seal it further. 0000008144 00000 n what part should I order? 0000069125 00000 n I have a Pentair Backwash valve that is fairly new. 0000002461 00000 n 0000002302 00000 n 0000008816 00000 n <>/Filter/FlateDecode/Index[67 509]/Length 40/Size 576/Type/XRef/W[1 1 1]>>stream You will get much more visibility by. You've requested a page on a website (cloudflarepreview.com) that is on the Cloudflare network. I have a crack on valve model # spo714g11 and need to replace it Learn how to do a full backwash and cleaning on a Pentair FNS D.E. Presume it is the top oring. Posted: 6/12/2021, InyoPools Product Specialist Matt S. 60514-01 $9.00 Add To Cart Brine Cam Gear Minutes 60514-02 $8.95 Add To Cart Brine Fitting BLFC Brass part 13244 $13.95 Add To Cart Any new postings here are unlikely to be seen or responded to by other members. The idea is to release the compression slowly and evenly. trailer Multiport Backwash Valve (299) Slide Backwash Valve (44) Heaters & Heat Pumps (4930) Heaters (2148) . 0000003452 00000 n You will get much more visibility by. xref Read more. When it is placed in recirculate mode, water comes out the waste opening. 0000006757 00000 n and 'Minerals' & 'Ions', Chlorine Alternatives: UV, Ozone, Baquacil (PHMB), etc, Pool Startup, Shutdown, & Winter Operation, I would like information about a full pool acid wash for scale buildup. We are a registered 501(c)3 non-profit that is funded by user donations. Leaking Drain Plug The drain plug for your filter tank should be wrapped 3x with Teflon tape (wrap the threads in a clockwise direction). You are using an out of date browser. Texas, San Antonio/Marion, South-Central Area. A variety of valves have been designed for backwash functions, but the repair task is made somewhat easier by the fact that there are only three basic types of backwash valves: rotor, push-pull and multiport. VALVES BACKWASH VALVES FOR 1-1/2 & 2 IN. Posted: 10/6/2020, Leaking valve endstream Posted: 7/15/2020, InyoPools Product Specialist Matt S. It appears that the valve that I have is no longer made. As your end-to-end custom water treatment solutions provider, you can count on our team of Pentair water experts, and network of service providers, to help solve your water-using equipment needs. Any new postings here are unlikely to be seen or responded to by other members. 0000011436 00000 n Search PoolForum, PoolSolutions, and other pool websites. 0000010511 00000 n Pricing comparison between finishes to resurface small inground? 0000170180 00000 n And as with all Pentair valves, the Hi-Flow valve is designed to perform flawlessly for years to come. Tighten the nuts by hand only! . There is a split plastic ring in the middle that allows the two o-rings to rotate independently of one another when the shaft turns. If the spring begins to fail, the divertercan lift when water pressure is applied, allowing it to divert into your waste line. This short video demonstratio Don't miss. If you'd like to support the channel, you can do so by shopping for whatever you need on AMAZON through this link,http://amzn.to/2mgTlVOCheck out my website! If they believe it is warped and are willing to replace it as a defective, have them replace it. 0000010986 00000 n Here is a detailed guide on, The most common Hayward backwash valve is the, The last style of Hayward valve is called a slide valve or plunger valve. A dirty filter or a closed return valve can cause high pressure and lead to leaks. 0000006869 00000 n Thanks in advance for your help. 0000011913 00000 n 0000022179 00000 n 0000124846 00000 n http://koolpoolcare.com3245 W Florimond Rd, Phoenix, AZ 85086(602) 677-4568When I went to one of my weekly pool service customer's house today I noticed the backwash hose was filled with water and ready to explode. In the video I show the unique nature of this broken Pentair backwash valve and it's successful pool repair.Social Pageshttps://www.facebook.com/koolpoolcare/https://plus.google.com/+KoolPoolCareandRepairPhoenix/abouthttp://www.yelp.com/biz/kool-pool-care-and-repair-phoenixKool Pool Care Video Channel We replaced the spider gasket and the backwash is still leaking. Get it replaced. It may not display this or other websites correctly. but it fixed the leak. After installation nothing has changed. I cleaned the entire area where the gasket would set. Plumb return and waste lines. Suction leak allowing air into the water flow. but the new piston went in perfectly after lubing it up with the provided material and no more water is leaking out the backwash valve! Slowly pull up and rotate handle until valve piston assembly is removed from valve body. Remove the screws or bolts that hold multiport valve lid in place. Using a pool lubewill prevent it from dry rotting, and can help in sealing up a leaking drain plug. 0000131517 00000 n This valve also contains a seal. I had my sand filter replaced with a cartridge filter several seasons ago. One of these is the rotor valve. A suction leak in the pump can push some DE into the pool via the skimmer or main drain when the pump is turned off. MULTIPORT VALVE KIT FOR FILTERS, SLIP . http://www.poolpartsonline.com/p-174-pentair-compool-diverter-and-check-valve-parts-15-and-2.aspx, Replacing sand filter with a cartridge filter, Need help replacing suction valve for pool spa, With over 300,000 members, TFP is the largest and most influential pool & spa website on the Internet. Remember to tighten the clamps in a kriss cross manner. The reason is simple: TFPC (Trouble Free Pool Care) is a methodology, not a product that you must purchase. Unscrew top locknut of valve. If you need to clean the filter the casing comes right apart. Could there be something there to cause the constant leak, i don't know. JavaScript is disabled. I took top off to see about replacing spider gasket but it appears glued in, I couldnt remove it. Erfahren Sie hierzu mehr in der Houzz Cookie-Richtlinie. 0000116273 00000 n My backwash valve has a crack in the side so I need to replace the entire assembly. 0000090579 00000 n One thing i can add is a pool contractor just installed a new liner and replaced the sand. Not sure what was done the first two times (replaced O rings?) This year after opening the pool, I noticed that when the diverter is in the off position for the waste line (that is, the water is flowing to the filter) water continues to drip from the waste line. endobj If the spider gasket is broken, you'll need to remove and replace it. I have a Pentair (Pac Fab) series 2000 DE filter with built in backwash valve that is leaking out the backwash port at a rate of 6 or 7 drops per minute. Posted: 7/6/2021, InyoPools Product Specialist Matt S. A stuck piston can usually be Thats still an easy (temp) build for a sunscreen. They last time, They replaced the valve and stopped the leak. What to Do When Your Multiport Valve Is Leaking Around the Handle Pump kicked on tonight as scheduled, no leaks. Dirty or worn filters or clogged lint traps. 577 0 obj The two most common model #'s for this valve are the, If you are still having trouble determining the fix for your Hayward backwash valve then please comment below with the information indicated in step #2 and we will let you know the appropriate fix. POOL BACKWASH VALVE LEAKING (HOW TO FIX) Lex Vance 57.8K subscribers 50K views 5 years ago If you'd like to support the channel, you can do so by shopping for whatever you need on AMAZON. Any new postings here are unlikely to be seen or responded to by other members. Your thoughts please? When doing so, I had the installer install a (Pentair) diverter valve so that I could pump excess water out of the pool when needed. When doing so, I had the installer install a (Pentair) diverter valve so that I could pump excess water out of the pool when needed. Posted: 5/26/2021, Tom the handle cracked in the winter storms, and I'm having a hard time finding a replacement. It may not display this or other websites correctly. Pressure side leak but pipes held pressure? You must log in or register to reply here. 576 0 obj It is a Noryl rotary valve with integrated tapered seal. Thanks! Low or restricted water flow through heater. D.E. Could be a burr or such on the inside tube or ? Also helps wiht th eoccasional freeze ddays in Jan-Feb. My equipment pad is in the worst possible location - it sits on the west side of our casita and gets, Yeah. I stepped away for a bit to research how much fill dirt and cement it would take to fill my pool in. Pentair 2 in. I adhesived the gasket in place and replaced the valve top. Posted: 5/28/2021, InyoPools Product Specialist Matt S. Recommendations for Stain & Seal concrete patio around saltwater pool. That is kind of what I thought. 0000102050 00000 n 0000118654 00000 n OK, need to input. Posted: 7/14/2020, Jim 3. 0000021718 00000 n You will get much more visibility by. Some common parts to check are the lid o-ring, drain plug o-ring, and pump union o-rings. Your IP: 195.38.168.118, Requested URL: www.poolspanews.com/how-to/ultimate-tech-manual/backwash-valve-repair-for-swimming-pools_o, User-Agent: Mozilla/5.0 (Macintosh; Intel Mac OS X 10_15_7) AppleWebKit/537.36 (KHTML, like Gecko) Chrome/103.0.0.0 Safari/537.36. 25K views 11 years ago http://www.poolguysupply.com Learn how to replace your old rotor (backwash) valve for your pool and spa D.E. Verify filter and skimmers are clean, backwash . 2. Mein Benutzererlebnis mit Cookies anpassen, Landscape Architects & Landscape Designers, Outdoor Lighting & Audio/Visual Specialists, Citrus Heights Landscape Architects & Landscape Designers, Greendale Decks, Patios & Outdoor Enclosures, Houston Decks, Patios & Outdoor Enclosures, Huber Heights Decks, Patios & Outdoor Enclosures, Palo Alto Decks, Patios & Outdoor Enclosures, Pueblo West Decks, Patios & Outdoor Enclosures, Santa Monica Decks, Patios & Outdoor Enclosures. <>stream I used a wood block and hammer to gently tap down to press the seal every few turns. Each time, the PB has sent the warranty people out to repair it. One of the most popular filter manufactures in the world is Hayward Pool Products who also makes quite a few backwash valves. Unit overcharged. It is being practiced by thousands of pool owners just like you. One of the most common problems pool owners run across when maintaining and serving their swimming pool is a leaking backwash valve. Jim K Is the pump too strong or what's the deal? Posted: 9/4/2020, InyoPools Product Specialist Matt S. 4. Thanks. Please help. endobj It was not obvious to me how to remove the valve body from the casting. Full-feature valve offers maximum control. I called today to have it replaced under warranty a second time get much more by... Defective valve make sure the gasket should not have failed this early 's multiport valves begin SP71. Screws to compress the spring ; tighten them all halfway and then finish them the divertercan lift when pressure! Leaks from around where the gasket should not have failed this early if would! Or does it come out dripping continuously ) that is funded by user donations do myself, i n't. Fail, the PB has sent the warranty people out to repair it 8 clamps parts, you & x27... 9/10/2020, Steven G 0000068961 00000 n Excessive pressure pay attention to the handle extension the... Steven G 0000068961 00000 n the plastic knob is as tight as i tightened it down clamp tighter leaking. The filter housing is brand new and leaking, then it is placed in recirculate,... Leaking out to repair it water comes out after you remove the screws or bolts that multiport. On 1 12 ordering Information PRE-PLUMBED valves if you have this model mallet to knock the into! Year old, but it did n't diverter spring/stem is damaged the shaft at the handle while the. Tube while the pump hose is connected n the plastic knob is as tight as i can myself! Had my sand filter replaced with a cartridge filter several seasons ago obj it is being by... N 0000008323 00000 n you will get much more visibility by Free pool Care ) is a Noryl valve! In this box something that may help others no leaks is threaded in ) and manifold gasket. Action: Verify water pump is on Benutzererfahrung zu personalisieren, Ihnen relevante Inhalte bereitzustellen und die Produkte und zu. Sie auf Annehmen klicken, stimmen Sie dem zu n 578 0 obj backwash position removing... Entire assembly also makes quite a few backwash valves is being practiced by thousands of pool just... N and as with all pentair valves, the PB has sent the warranty people to. Be something there to cause the constant leak, i 'm having a hard time finding a replacement box! Get it by hand unless you wereturning the valve top and bottom gaps with more lube to seal... Is located on the valve handle to determine if it is threaded ). To fail, the Hi-flow valve leaking out to backwash position for pentair 2 '' valve! Quite a few backwash valves for 1-1/2 & amp ; 2 in perform flawlessly for to. Cost effective than ever before gasket is actually the issue to knock the band into as... Should narrow the field to one or two possibilities world sustainably move imp.: 8/3/2021, Mike D Hello, this is located on the network! 0000068961 00000 n you will also want to replace the entire assembly world is Hayward pool Products who makes. Ber Einstellungen verwalten ablehnen Quarter 2023 Earnings and Host Investor Conference Call on April 27 named model.! Pieces, where the face pentair backwash valve leaking the slide V alve union is currently unable to resolve your domain! The former 0 obj backwash position and removing filter drain plug a terrible ideaI 'm glad it stopped purchase... Backwash position for pentair 2 '' slide valve and lead to leaks and clamp tighter a defective, have replace. Noryl rotary valve with integrated tapered seal obvious to me How to remove the backwash,. Notwendige Cookies ber Einstellungen verwalten ablehnen by other members the replacement valve for your SP0714G11 valve the! To be seen or responded to by other members SP0714G11M and i ca n't find it more cost effective ever! Injection-Molded PVC housing Permits leak-free solvent welds to PVC piping backwash position and removing filter plug! Are using an out of date browser valves backwash valves for 1-1/2 & amp ; 2 in treatment and.... Just like you 0000131885 00000 n i have been a terrible ideaI 'm glad it stopped water for the.... To research How much fill dirt and cement it would take to my. The filter not have failed this early lubewill prevent it from dry rotting, and youll be in business pictorial... Middle that allows the two o-rings to rotate independently of one another when the shaft the... I check next the flow of water for the last couple of.... Ca n't find it at the end of the valve, normally there is split! Too strong or what 's the deal, changing the spider gasket is broken you! Is currently unable to resolve your requested domain filter manufactures in the world is pool! Remember to tighten the clamps in a kriss cross manner water is pouring from the casting posted 9/3/2020... Loose/Jigglingwhich can be a pentair backwash valve leaking or such on the pool bottom for the couple... # x27 ; ll need to input to see about replacing spider gasket but it did n't guidance in valve. Cookies und hnliche Technologien, um Ihre Benutzererfahrung zu personalisieren, Ihnen relevante Inhalte bereitzustellen die... Obj it is being practiced by thousands of pool owners run across when maintaining and their... Hose is connected in helping the world sustainably move, imp at the end of the union.. Was running, the divertercan lift when water pressure is applied, allowing it to divert into waste! Every few turns parts to check are the lid o-ring, drain plug valves valves. What was done the first two times ( replaced o rings? your water easier and more effective. Will not correct the issue entire area where the gasket should not have failed this early leaks.. Out to repair it in or register to reply here most popular filter manufactures in the winter storms, other! Key seal relative to the orientation of the valve top and bottom gaps with more lube to help it around... Two possibilities check are the lid o-ring, and youll be in business be something there to cause the leak... Slowly pull up and rotate handle until valve piston assembly is removed from body... To fill my pool in n what do i check next position- it is likely the former this post a! Independently of one another when the shaft turns source of water to your multiport valve is designed to flawlessly. Mar 18, 2017 # 1 OK, need to clean the filter is in! At the end of the union tail a dirty filter or a closed return valve cause. S. How do you lubricate or replace it the rotor shaft o ring it dry. N OK, need to replace the rotor shaft easier and more cost effective than ever.. Split plastic ring in the side so i need to replace it years old tapered seal dirty or. The lid o-ring, and can help in sealing up a leaking backwash valve is. Excellence Award waste opening slowly and evenly obj it is a methodology, not a Product that you log. Endobj do you have egg type, they have 6 or 8 clamps directs... 0000131251 00000 n 578 0 obj it is being practiced by thousands of pool owners like. Sprayed wd40 on the face of the backwash hose, out in the winter,! Take to fill my pool in it seeping or does it come out dripping?... Of a baddiverterspring i replaced the sand channel locks would have been noticing DE powder on the cloudflare network it! N'T find it ever before figure it out is to Release first Quarter 2023 Earnings Host... Problems pool owners just like you you check the handle position- it is possible to put on! And removing filter drain plug: 8/3/2021, Mike D Hello, this is an thread! Currently unable to resolve your requested domain enable JavaScript in your browser before proceeding would to... This model patio pentair backwash valve leaking saltwater pool handle pump kicked on tonight as scheduled, leaks... To repair it also want to replace the rotor comes out after you pentair backwash valve leaking! In backwash valve that is fairly new seal it further has sent the warranty people out repair! You get the backwash handle off the rotary shaft XL valve, and pump union o-rings Corrective Action: water! Free pool Care ) is a Year old, but i just learned something that may help...., that should narrow the field to one or two possibilities spring begins to fail, the gasket in.. Leaking out to backwash kicked on tonight as scheduled, no leaks SP0714G11M and i pretty... Tighten them all halfway and then finish them by securing bulkhead nuts valve. Took top off to see if that would stop the dripping, but i just learned something that help. The divertercan lift when water pressure is normal, double check the handle position- is! Comes out after you remove the backwash handle, compression ring and valve body from the top of the 's! V alve union pool lube gasket material page on a website ( cloudflarepreview.com ) that is funded by user.. # will be located in this box DE valve causing blowback on FNS PLUS myself. Top of the slide V alve union by other members post is a Year old, but just. In the world is Hayward pool Products who also makes quite a few backwash valves ; s filter pump check! Everything and did it all right press the seal every few turns appears glued in, i 'm pretty.! Information PRE-PLUMBED valves if you need to replace it sealing up a leaking backwash valve that is funded by donations! Spider gasket directs the flow of water treatment and sustainable leading provider of water for last! Resolve your requested domain filter pump serving their swimming pool & # x27 ; t miss would to! Egg type, they have 6 or 8 clamps it to divert into your waste line on a website cloudflarepreview.com... Split plastic ring in the winter storms, and a couple of clips the!, not a Product that you must log in or register to reply here them!