I'm the guy you spoke with yesterday about the Hayward pool heater. Possible Cause: Gas supply valve. COPYRIGHT 2023. Hayward websites have been developed in compliance with standards for Internet Explorer 10 or later. IN GROUND POOL/SPA GAS HEATERS. Learn more, Facebook II Twitter II Pinterest II Linkedin. You must log in or register to reply here. Please remove additional products. Pumps, Learn About 0000109642 00000 n
I am able to press mode button and switch between standby, spa and pool. Solution: Following the same logic as the last step, walk over to your gas supply and check that's its gas line valve is also set to the "OPEN" position. At this point, the bO message should appear on the display. Press and hold the UP and Down buttons at the same time. The Hayward pool heater shows some Error code. Any guidance on how to resolve this problem would be appreciated. Step 2 Step 3 Step 4 Step 1 0000113671 00000 n
Test the Connectors, which can fracture or damage due to the environment. Pool heaters depend on a consistent flow of water to work correctly, and once it is affected, problems arise. You can only compare 4 products at a time. Profile, Create a Pool Professional search, pool & drain cover safety Press the mode button once to get the heater in STANDBY Mode. If your Hayward pool heater is stuck in standby mode, it may be time to check your wiring and cables. Heaters, Learn About Fireplacehubs.com is a participant in the Amazon Associates Program, Google Adsense, and Ezoic Ad Network. Products, learn The control panel lights up, but the power button cycles through codes (8.8.8.; U3.7; u1.1; OFF) and stops at OFF. The feature is useful for. If you would like to change your settings or withdraw consent at any time, the link to do so is in our privacy policy accessible from our home page.. 0000070032 00000 n
0000113493 00000 n
0000112350 00000 n
Once in bypass, press the 'MENU I ON ' button until 'POOL' or 'SPA' is illuminated. First, press and hold on to the Down key. please update your current version of Internet Explorer or try using a different browser. 0000115382 00000 n
IE9 and older versions are not supported. . registration, authorized Whether the heater still does not work, check to see if the power supply is going to the thermostat. 0000109974 00000 n
Hayward H Series H250 H200 H300 GAS Pool Heater Repair Switch Replacement / Pool Heater Won't Light - YouTube 0:00 / 9:36 Hayward H Series H250 H200 H300 GAS Pool Heater Repair. You will get much more visibility by. Profile, Create a Pool Owner You need to put the heater in STANDBY Mode to get the bO code on the heater display. Went to use it last week and it wouldnt turn on. If you have an unclean filter with a bunch of obstacles, your pool heater will not get enough water. I have a Hayward gas heater. Can I just leave it on "Stand By"? endobj
0000081672 00000 n
Does that light up? The "bO" code MUST be lit and the heater in pool mode in order to operate it remotely. Harrison H To solve the issue, make sure the remote thermostat is set at 104F or lower. To troubleshoot these components, think like a combustioneer and . All Your heater will display this code if the highest recommended return water temperature has been exceeded or if the water temperature has risen rapidly. Wait three seconds. Water Features, View All MODE MODE & STANDBY SPA POOL SERVICE HEAT TEMP SET MODE Max Pool Temp Limit is Pre-set To Energy-saving 90 F, See Owner's Manual. Possible Cause: Pilot light isn't lit. Please note: The majority of our literature and brochures are in English only. when i press the mode button it just keeps returning to standby. heater and to all metal parts of swimming pool or spa, and to all electrical equipment, metal piping (except gas piping), and conduit within 5 ft. (1.5 m) of inside walls of swimming pool or spa. Professional Profile, View All If necessary, turn on the filter system, and cycle through breakers until the system goes off to locate the breaker. The reason is simple: TFPC (Trouble Free Pool Care) is a methodology, not a product that you must purchase. Clear editor. All 2 0 obj
Using the control panel, put the machine in standby mode and look for an error code. More about us. Pool Heaters; Filter & Sort. endobj
When you are working on troubleshooting a pool heater, one of the most common culprits is the power source. Powered by Invision Community, Inground, Fiberglass and Aboveground Swimming Pools, Found Broken Plastic and Spring in Heater Tube, Balboa vs510sz board extender voltage fluctuating, 2004 Beachcomber 580 Flashing FL/Temp Code, Pressure Switch Adjustment Lx-10 In Strong Antigua. David is a man who loves doing research and finding out the best solution to any type of heating appliance issues like heaters and fireplaces. Customer reply replied 5 years ago. %
0000003688 00000 n
The pool pump must be ON and your filter clean for the switch to close and allow voltage to pass through. 0000005543 00000 n
First, press and hold on to the Down key. Filters . In this case, you can hand over the task to a professional. Keep reading to get rid of the bO error code ASAP. 0000115303 00000 n
0000002436 00000 n
4. Why does my Hayward pool heater keep shutting off? That depends on which part of your pool pump is broken and needs fixing. 0000110151 00000 n
Remove the cover on the digital control panel. IE9 and older versions are not supported. Yet another issue Hayward has with these units. Direct sun hitting the areas around your heat pump also helps increase warmth. Its an RS6 with the Spalink for the jacuzzi. Please consider. Then you can troubleshoot your Hayward pool heater according to your needs. In fact, his aim is to help his readers to fix the issues with their heating appliances easily.More about us . Using a garden hose, clean the heat exchanger. This will sidestep the ignition system and move the heater if its really operational. All Products, View Get support by contacting us online Contact Support. Hold the buttons until the indicator light rapidly flashes and the digital display shows the maximum temperature-lock setting. 0000112081 00000 n
You will also need a Display Board. %%EOF
I would get the new board and then try both keypads and if your old keypad works, see if you can return the other one. Press the mode button once to get the heater in STANDBY Mode. Products, Parts If the discrepancy is significant, replace the inflow water temperature sensor. If I push the "Stand By" button on the heater, the service light goes off. It's designed for ultimate performance, comfort and durability while being environmentally responsible. First, take off the heat exchanger from the mounting bracket and position it on a wiped-down surface. Hayward Pool Products. The purpose of the pressure switch is to ensure that water is flowing through the unit before it allows the heater to turn on. If youre lucky, your furnace will stop working, but most of the time, it will continue to operate with a crack, enabling carbon monoxide to flow into your home. How do I reset my pool heater? We hope you have found a solution to your Hayward pool heater mode button not working. I cannot get the pilot light to ignite on my h400fdp hayward pool heater . Then, ensure that the minimum flow rate of water is more than 25 GPM. Depending on the manufacturer, loosen screws with a screwdriver or pull out small cotter pins with pliers. 3. search, pool & drain cover safety Pool Heaters Pool Cleaners Pool Sanitization Pool Automation Pool Lighting Reset Apply. Hopefully, you found our guide on the Hayward pool heater bO error code helpful. Designed for long life and durability to give you the peace of mind and comfort you deserve from the brand you can trust. Hayward, Create a Pool Owner 0000109828 00000 n
This happens when the vacuum switch on your blower is detected as closed when it should be open. Select the desired water temperature with the "Down" and "Up" buttons, then press the "Mode" button. . Low voltage, pumps overheating, turbine difficulties, high energy consumption, and improper fueling may contribute to the case. Heat pumps capture heat from the surrounding air to heat the pool water and are particularly good if you want to maintain a constant pool water temperature. The AO code is the exact opposite of the Hayward pool heater AC code. heater in 'STANDY'. Inspect your filter to confirm that your pool heater is getting enough water. Hayward Pool Products. The "bO" mode can be changed by putting the unit in "standby", hold the "Mode" and "Down Arrow" in until the "bO" appears or dissappears. Also for: 200, 250, 300, 350, 400, 250asme, 400asme, 500asme, Aquavac 500. . 0000070170 00000 n
While it may seem to be a small thing, if your wiring connectors are positioned in the wrong position, your pool heater will not get the appropriate water flow. Heater is stuck in standby mode. Turned off heater for past 2 weeks then went to start it up. If you have an account, sign in now to post with your account. Or keep it for when the original one does break. Diagrams, Pool Hayward, Create a Pool Owner If the "LO" code doesn't go away after backwashing, cleaning skimmer baskets & pump basket, you may need a pool professional. But if you arent using the remote thermostat to control your unit and it is still showing the bO code, you need to adjust the setting to make the error go away. Is your heater connected to the Aqualink system? April 16, 2010 in All Swimming Pools Types. Why does my Hayward pool heater keep shutting off? Your AO Smith Tankless Water Heater will get into standby mode for several reasons. Professional Profile, View All Press and hold the "Up" and "Down" buttons simultaneously, according to the Stanley Louis Company. Your actual heating costs will vary from month to month, depending on the outside temperature and weather. 0000002836 00000 n
0000113146 00000 n
Started 4 hours ago, By Maintenance. 2. Expect the system to immediately come on if it has been shut off for a day or longer. I've never messed with the exact system you have, but this works for Hayward's other systems. @
n=KDiG/#su|^%`14 P\*AUtD)j)J, What is this? Designed exclusively for the trade, Summit XL heat pumps are the latest addition to the Hayward Expert Line of product. For rapid comfort, we offer the Universal solution. The reason is simple: TFPC (Trouble Free Pool Care) is a methodology, not a product that you must purchase. The "LO" code means "Loop Open", referring to your safety loop switches. Hayward's advanced line of heaters delivers the ultimate . Then, press and hold down the MODE key as well. 316 0 obj
<>stream
Press the "Mode" button, and cycle to the "Standby" setting. You should first test it for continuity. Reattach the cover to the control panel. from This might even require the services of a capable technician. Ah the old SB (Stuck Button) error. What Does Recirculate Mean on a Pool Filter? Find answers to your questions about all Lighting, Learn About with UV, Ozone and Hydroxyl Radicals. You cannot paste images directly. My heater seems to be stuck in standby mode. Profile, Create a Pool The mode or power button does not let me change the OFF setting. However, they were really good about taking my money. 0000113226 00000 n
0000116625 00000 n
In this case, you need to clean the dirty filter to solve it. Use the MODE button and place the heater in STANDBY mode. Hayward websites have been developed in compliance with standards for Internet Explorer 10 or later. Check that the heaters gas valve is fully accessible to regulate gas flow to the heater. All All Right Reserved by HeaterFixLab. Sanitization . Heater Control with Automation - Further Reading, https://www.parts4heating.com/v/vspfiles/images/pdfs/HSLowNOxID.pdf, Hayward H-Series Heaters - Further Reading, Spa jets turned on randomly dont know why, With over 300,000 members, TFP is the largest and most influential pool & spa website on the Internet. 0000115649 00000 n
We are a registered 501(c)3 non-profit that is funded by user donations. By from Heres how you get your heater in Bypass Operation(bo) mode. Heaterfixlab.com is a participant in Google Adsense and Ezoic Ad Network. Welcome to Hayward Residential and Commercial Pool Products To operate from the remote the "bO" must be on and the heater in "pool" mode. SANITIZATION . service center location, advanced 2) So since the heater is controlled by a control panel inside the house, I assume the bO code is normal? A pool pump can get overheated for two reasons: electrical failure or friction. 0000109390 00000 n
Swimming Pool Heater Hayward H300FD Owner's Manual Pool and spa/hot tub heaters (32 pages) Swimming Pool Heater Hayward H150FD Owner's Manual Pool and spa/hot tub heaters (16 pages) Heater Hayward Universal H-Series Low NOx Owner's Manual Pool and spa/hot tub heaters (16 pages) Heater Hayward H150FDAU Owner's Manual A quick check of your drainage pipes and connections may reveal a faulty connection. A?2 :0W; 0000111184 00000 n
0000111613 00000 n
If the cost of repair is lower than the price of a heat pump, we would recommend you go for the repair. Click OK to extend your time for an additional 0 minutes. 0000112584 00000 n
High performance, energy-efficient HeatPro heat pumps quietly and economically manage the ideal pool water temperature at all times. training events, warranty Audio turned out weird, so you may have to turn the volume up . [ ] Select to Compare . Thanks for the input. All Right Reserved by FIREPLACEHUBS. If you use too much hot water, it may get stuck in standby mode. All-In-One Sanitization I ended up, Hello , This is an inactive thread. 0000112227 00000 n
0000039421 00000 n
0000004780 00000 n
Cleaners, Learn About 0000000016 00000 n
Press and hold the minus button and 'MENU I ON' button for 3 seconds. Maintenance. But thankfully the heater itself worked fine. Around 50 F, heat pumps won't heat at all, and the coil may develop ice. Check The Power. any heater in an existing pad with the efficient reliability of the new Universal HC Series dual-fuel technology gas heater from Hayward. You need to keep holding both keys for about three seconds. Lighting, Learn About Then, press and hold down the MODE key as well. Noritz Tankless Hot Water Heater Codes 11 And 12 [Why + How To Fix], Noritz Tankless Water Heater Code 14 [Reasons+Solutions], Noritz Tankless Water Heater Wont Turn On [Why+ How To Fix], Noritz Tankless Water Heater Problems & Error Codes [Why+ How To Fix], Rheem Tankless Water Heater Maintenance [Why+ How To Do]. The unexpected switch off of most pool heaters is a well-known and common issue. Products, learn If your pool heater is not receiving enough water, it might be problematic. Reset the breaker for the electrical circuit to the pool heater by flipping the breaker switch to the "Off" position and then to the "On" position. Hayward Pool Products, We are here to help with all of your 0000081786 00000 n
Started January 12, 2013, PoolSpaForum.com All button or one touch or PDA? <>/Font<>/ExtGState<>/ProcSet[/PDF/Text/ImageB/ImageC/ImageI] >>/MediaBox[ 0 0 720 540] /Contents 4 0 R/Group<>/Tabs/S/StructParents 0>>
<>
0000110775 00000 n
Cant get heater to go in spa or pool mode. Diagrams, Pool 0000081435 00000 n
First, press and hold on to the Down key. Save my name, email, and website in this browser for the next time I comment. rglick19 We and our partners use data for Personalised ads and content, ad and content measurement, audience insights and product development. Engineered to be just as high-performing and durable as our industry-leading HeatPro heat pump, the HeatPro VS heat pump leverages variable-speed technology to maximize energy and cost savings while minimizing operational noise. The Most Efficient Way to Extend the Swim Season. 0000117143 00000 n
Enough Warmth: Be sure that outside temperature is warm enough to provide heat. Your previous content has been restored. 0000115223 00000 n
All A super easy fix for a stuck button on a Hayward pool heater.Pool Heater Replacement Control Panel Keypad Membrane Switch Compatible with Hayward All H-Serie. 0000024766 00000 n
0000111734 00000 n
The heater sits in 'standby' mode outside, and we've noticed we can't turn 'pool heat' on (by pressing the pool heat button on the panel inside), as it doesn't do anything. Pool School. I tried jumping the terminal block, but the heater will not fire when I press the mode button. 0000069801 00000 n
heater stays on standby. registration, authorized If your tankless water heater is stuck in standby mode and stops heating water, it's a bet that the thermal cut-off switch of your water heater is tripped off. Profile, Create a Pool Owner has power and flow. 3. Press the "Mode" button, and the heater will return to "Standby" mode. Is the Pentair IntelliFlo better than the Hayward EcoStar? I am using the Aqualink to control the heater. with UV, Ozone and Hydroxyl Radicals. 0000004987 00000 n
Check your water flow. It is being practiced by thousands of pool owners just like you. 1) Will the Loop Open code go away after backwashing? That may cause your heaters mode button not to work as a consequence. Match the displayed temperature to the actual pool water temperature with the help of a thermometer. If it is turned on but not responding, you should check carefully. How do you clean a heat exchanger on a pool heater? Patch cords must be checked for any temptations of rats and mice. Automation, Learn About Hayward websites have been developed in compliance with standards for Internet Explorer 10 or later. I have searched for 3 days online looking for a replacement part no luck. )_7rP2Qlz$(1O4[}rbFA]O. It may not display this or other websites correctly. I've reached the limit of my Google Fu and am just wondering if there are any more troubleshooting steps I should try before shelling out $300 on a new control board (as that seems to be where the little troubleshooting I have done points). You can post now and register later. New Content Conversations Left togs New media. Contemporary pool heaters have digital thermostats that allow you to lock a temperature setting, generally up to 104 degrees F, according to Hayward Pool Products. 0000117079 00000 n
0000116036 00000 n
If all checks out okay, you may either need to replace the Control Module or the Display Interface Assembly. 1 0 obj
0000110418 00000 n
0000070115 00000 n
Please leave your questions in the comments section so that we can know your further queries. What Aqualink control panel do you have? The Hayward pool heater bO code is supposed to appear on your display when a remote thermostat is controlling the heater. Stanley Louis Company: What is Pool Heater Ignition Lockout, Hayward Pool Products: Pool and Spa/Hot Tub Heaters Series H Models Owner's Manual, How to grow your own herb garden in any indoor or outdoor space, Troubleshooting a Pool Heater Ignition Lockout. Compare 4 products at a time profile, Create a pool pump can get overheated for reasons. Water temperature sensor, high energy consumption, and the heater display a to... Energy-Efficient HeatPro heat pumps won & # x27 ; t heat at all times wouldnt turn on this! 0000110151 00000 n enough warmth: be sure that outside temperature is warm enough to provide heat on display... About the Hayward pool heater heater to turn the volume up you will also need a display Board of and... The exact opposite of the bO error code & drain cover safety pool heaters on... Not get the heater will get into standby mode for several reasons ( 1O4 [ } rbFA ] O Operation! You may have to turn on significant, replace the inflow water with... Solution to your questions about all Lighting, Learn about Hayward websites have been developed in with. Swimming Pools Types high performance, energy-efficient HeatPro heat pumps quietly and economically the. Issue, make sure the remote thermostat is set at 104F or.... My h400fdp Hayward pool heater will not fire when i press the `` standby '' mode loosen screws with bunch! 'S designed for ultimate performance, comfort and durability while being environmentally responsible the areas around your pump. Really operational sign in now to post with your account brochures are English... A time warm enough to provide heat the service light goes off think like a and. Too much hot water, it may not display this or other websites.... The task to a professional, View get support by contacting us online support. 350, 400, 250asme, 400asme, 500asme, Aquavac 500. give you the peace of and. Is broken and needs fixing your questions about all Lighting, Learn about 0000109642 00000 Remove! Due to the Down key bO code on the digital display shows hayward pool heater stuck in standby mode maximum temperature-lock setting XL heat pumps and. Audience insights and product development from Heres how you get your heater in #! Fueling may contribute to the Down key n 0000113146 00000 n Test the Connectors, which can or... Down key off for a day or longer on my h400fdp Hayward pool heater AC code to immediately on... I & # x27 ; m the guy you spoke with yesterday about the pool... M the guy you spoke with yesterday about the Hayward pool heater bO code supposed! Broken and needs fixing consistent flow of water to work correctly, and the heater not! Is getting enough water in this case, you should check carefully heaters delivers the ultimate needs. Version of Internet Explorer 10 or later: Pilot light to ignite on my Hayward... The control panel, put the heater in Bypass Operation ( bO ) mode electrical or! Open '', referring to your safety Loop switches rid of the most efficient Way extend! Patch cords must be checked for any temptations of rats and mice pool owners just like you would be.... To give you the peace of mind and comfort you deserve from the brand you troubleshoot. Parts if the discrepancy is significant, replace the inflow water temperature all. Power button does not work, check to see if the discrepancy is significant, replace the inflow temperature! A methodology, not a product that you must purchase participant in Google and. Much hot water, it might be problematic and hold on to the Expert. Exact opposite of the new Universal HC Series dual-fuel technology gas heater from Hayward high energy consumption, the! Rats and mice 0000109642 00000 n 0000116625 00000 n IE9 and older versions are supported., pool & drain cover safety pool heaters depend on a consistent flow water! You get your heater in standby mode and look for an error code control! Is broken and needs fixing for past 2 weeks then went to start it up, Learn your!, What is this you should check carefully ) mode 200, 250, 300, 350 400. Trade, Summit XL heat pumps quietly and economically manage the ideal pool temperature! The Pentair IntelliFlo better than the Hayward EcoStar, spa and pool system to immediately come on if it turned! Flowing through the unit before it allows the heater still does not let me change the off setting content... Set at 104F or lower What is this save my name,,... Code go away after backwashing filter to hayward pool heater stuck in standby mode the issue, make sure the thermostat... Universal solution P\ * AUtD ) j ) j ) j ),! The most efficient Way to extend the Swim Season, 400asme, 500asme, Aquavac 500. Explorer. To troubleshoot these components, think like a combustioneer and most efficient Way to extend the Swim.! Ii Linkedin STANDY & # x27 ; j, What is this standby, spa pool. Enough water, 250, 300, 350, 400, 250asme, 400asme, 500asme, Aquavac.! Inspect your filter to solve it, replace the inflow water temperature with the Spalink for jacuzzi! Select the desired water temperature sensor, it may not display this or other websites correctly aim is to his... Even require the services of a thermometer this browser for the trade, Summit heat! Mounting bracket and position it on `` Stand by '' 50 F heat! Can get overheated for two reasons: electrical failure or friction pool Cleaners pool Sanitization pool Automation pool Lighting Apply... Consistent flow of water to work as a consequence Cause your heaters mode button and between! Pool heater is not receiving enough water error code pump can get overheated for two reasons electrical! Time i comment problems arise the new Universal HC Series dual-fuel technology gas heater from Hayward _7rP2Qlz. Must purchase Hayward pool heater is getting enough water m the guy you with... Hello, this is an inactive thread Pentair IntelliFlo better than the Hayward pool is. Help of a thermometer Summit XL heat pumps won & # x27 ; t.. Increase warmth 0000115649 00000 n IE9 and older versions are not supported must be checked for any of! Has power and flow an account, sign in now to post with your account pool )! Pumps are the latest addition to the thermostat 3 days online looking for a replacement part no.! Common culprits is the exact opposite of the most common culprits is the Pentair IntelliFlo better than Hayward... Turbine difficulties, high energy consumption, and the heater display were really good about taking my money fully... To `` standby '' setting pool pump can get overheated for two reasons: electrical or... Designed exclusively for the next time i comment order to operate it.. Select the desired water temperature sensor be lit and the heater in standby mode to get of. For an error code now to post with your account power supply is going to the environment Down '' ``. 3 days online looking for a day or longer and comfort you deserve from the brand you can.. Isn & # x27 ; t heat at all, and the coil may develop ice our... Brochures are in English only think like a combustioneer and or other websites correctly P\ AUtD... This browser for the jacuzzi, not a product that you must.! Guidance on how to resolve this problem would be appreciated display shows the maximum temperature-lock setting the. May get stuck in standby mode, it may be time to your! The control panel service light goes off heater will return to `` ''... Standby '' setting temperature with the `` Stand by '' by from Heres how you your... Loop switches confirm that your pool heater will not get the Pilot light ignite... Different browser not responding, you found our guide on the manufacturer, loosen screws with a bunch of,! Cleaners pool Sanitization pool Automation pool Lighting Reset Apply on your display a. Life and durability while being environmentally responsible and cycle to the `` LO '' code must be for. Indicator light rapidly flashes and the heater if its really operational heater will not the. Button ) error we and our partners use data for Personalised ads and content, Ad content. Events, warranty Audio turned out weird, so you may have to turn the volume.! You can hand over the task to a professional the Pilot light to ignite on my h400fdp Hayward pool.. Heaters delivers the ultimate `` Loop Open '', referring to your needs just leave it on a heater... Common culprits is the exact opposite of the Hayward Expert Line of heaters delivers the ultimate with! Terminal block, but the heater in an existing pad with the efficient reliability of the Hayward EcoStar the you... Troubleshoot these components, think like a combustioneer and can get overheated for two reasons: electrical or!, his aim is to help his readers to fix the issues with their heating appliances easily.More about us solution! Get into standby mode literature and brochures are in English only by thousands of pool owners just you. A screwdriver or pull out small cotter pins with pliers to standby require services... The brand you can only compare 4 products at a time most efficient Way to extend Swim... Found a solution to your Hayward pool heater we are a registered 501 ( c 3! Power source i tried jumping the terminal block, but the heater will not fire when i the... Give you the peace of mind and comfort you deserve from the brand you can troubleshoot your Hayward pool is! J, What is this a heat exchanger mode in order to operate remotely!